LabTech Flex-MVP Automatic Parallel Vacuum Concentrator

The Flex-MVP Automatic Parallel Vacuum Concentrator is a high-throughput, high-efficiency concentrator. Under heating, vacuum, and vortex oscillation conditions, it rapidly evaporates or concentrates multiple samples to a desired volume. Its combined overall and independent sealing design allows for both full-chamber sealing and individual sealing, enabling flexible addition or removal of concentration flasks without releasing the chamber pressure. This simplifies the concentration process, improves efficiency, and is widely applied in food, environmental, agricultural, and biological sample processing.

Key Features

The Flex-MVP Automatic Parallel Vacuum Concentrator independently controls each sample, allowing flexible handling, high concentration efficiency, user-friendly operation, and environmentally friendly performance.
  • Batch capacity: 16 positions, compatible with 200 mL, 50 mL, 40 mL, and other flask sizes.
  • Flexible handling: Combined overall and independent sealing design allows addition or removal of individual samples without pausing the instrument or releasing chamber pressure.
  • Independent tubing: Each flask has a separate sealed line and independent exhaust, preventing cross-sample liquid transfer due to bumping, avoiding contamination and backflow.
  • Easy observation: Fully transparent concentration chamber; flasks are suspended, and LED lighting allows monitoring of the sample bottom during operation.
  • Dual solvent and exhaust recovery: Dual-condensation tower design enables recovery of both solvent vapors and exhaust, ensuring environmental friendliness.
  • Touchscreen control: 10-inch touchscreen computer system.
  • User-friendly operation: Software allows real-time adjustment of temperature, vacuum, and shaking frequency; supports timed operations; graphical display of gradient curves; real-time monitoring of all parameters.
Environmental
Used for concentration and enrichment of semi-volatile organic compounds in soil, solid waste, air, and water samples.

EPA Method 8270D (SW-846): Semivolatile Organic Compounds by Gas Chromatography/Mass Spectrometry (GC/MS)

EPA Method 8100 (SW-846): Polynuclear Aromatic Hydrocarbons by Gas Chromatography

EPA Method 8082A (SW-846): Polychlorinated Biphenyls (PCBs) by Gas Chromatography

EPA Method 8081B / EPA Method 8141B: Organochlorine Pesticides by GC / Semivolatile Organics by GC/MS

EPA Method 1613B Tetra- through Octa-Chlorinated Dioxins and Furans by Isotope Dilution HRGC/HRMS

EPA Method 8032A (SW-846): Acrylamide by Gas Chromatography

EPA Method 610 (40 CFR Part 136): Polynuclear Aromatic Hydrocarbons (PAHs) by Liquid-Liquid Extraction and High-Performance Liquid Chromatography (HPLC) with UV Detection

EPA Method TO-13A (Compendium of Methods for Toxic Organic Air Pollutants): Determination of Polycyclic Aromatic Hydrocarbons (PAHs) in Ambient Air Using Gas Chromatography/Mass Spectrometry (GC/MS)

EPA Method TO-10A (Compendium of Methods for Toxic Organic Air Pollutants): Determination of Pesticides and Polychlorinated Biphenyls (PCBs) in Ambient Air Using Polyurethane Foam (PUF) Sampling and HPLC/UV Detection of Benzo[a]pyrene

EPA Method 3545A (SW-846): Pressurized Fluid Extraction (PFE) of Organics from Solids and Semisolids
Food & Beverage
Used for enrichment and concentration of pesticide residues, veterinary drug residues, and organic extracts in food, grain, oil, and agricultural products.

EPA Method 8270D: Semivolatile Organic Compounds by Gas Chromatography/Mass Spectrometry (GC/MS)

EPA Method 8081B: Organochlorine Pesticides by Gas Chromatography (GC) with Electron Capture Detector (ECD)

EPA Method 8141B: Organophosphorus Pesticides by Gas Chromatography

EPA Method 8321 / 8321B: Solvent-Extractable Nonvolatile Compounds by High-Performance Liquid Chromatography (HPLC) with TS-MS & UV Detection

EPA Method 531: Determination of Carbamate Pesticides in Food by Liquid Chromatography with Post-Column Derivatization or LC-MS/MS

EPA Method 1699: Residue Analysis of Veterinary Drugs in Animal Tissue by LC-MS/MS
Disease Control
Used for enrichment and concentration of pesticide residues, veterinary drug residues, and semi-volatile organics in food, agricultural products, and drinking water.

EPA Method 8270D: Semivolatile Organic Compounds by Gas Chromatography/Mass Spectrometry (GC/MS)

EPA Method 8081B: Organochlorine Pesticides by Gas Chromatography (GC) with Electron Capture Detector (ECD)

EPA Method 8141B: Organophosphorus Pesticides by Gas Chromatography

EPA Method 8321 / 8321B: Solvent-Extractable Nonvolatile Compounds by High-Performance Liquid Chromatography (HPLC) with TS-MS & UV Detection

EPA Method 531: Determination of Carbamate Pesticides in Food by Liquid Chromatography with Post-Column Derivatization or LC-MS/MS

EPA Method 1699: Residue Analysis of Veterinary Drugs in Animal Tissue by LC-MS/MS
Geology & Mining
Used for enrichment and concentration of semi-volatile organic pollutants in soil, solid waste, air, and water samples.

EPA Method 8270D (SW-846): Semivolatile Organic Compounds by Gas Chromatography/Mass Spectrometry (GC/MS)

EPA Method 8100 (SW-846): Polynuclear Aromatic Hydrocarbons by Gas Chromatography

EPA Method 8082A (SW-846): Polychlorinated Biphenyls (PCBs) by Gas Chromatography

EPA Method 8081B / EPA Method 8141B: Organochlorine Pesticides by GC / Semivolatile Organics by GC/MS

EPA Method 1613B Tetra- through Octa-Chlorinated Dioxins and Furans by Isotope Dilution HRGC/HRMS

EPA Method 8032A (SW-846): Acrylamide by Gas Chromatography

EPA Method 610 (40 CFR Part 136): Polynuclear Aromatic Hydrocarbons (PAHs) by Liquid-Liquid Extraction and High-Performance Liquid Chromatography (HPLC) with UV Detection

EPA Method TO-13A (Compendium of Methods for Toxic Organic Air Pollutants): Determination of Polycyclic Aromatic Hydrocarbons (PAHs) in Ambient Air Using Gas Chromatography/Mass Spectrometry (GC/MS)

EPA Method TO-10A (Compendium of Methods for Toxic Organic Air Pollutants): Determination of Pesticides and Polychlorinated Biphenyls (PCBs) in Ambient Air Using Polyurethane Foam (PUF) Sampling and HPLC/UV Detection of Benzo[a]pyrene

EPA Method 3545A (SW-846): Pressurized Fluid Extraction (PFE) of Organics from Solids and Semisolids
Forensics
Used for enrichment and concentration of drugs and organic pollutants in blood, urine, wastewater, and other biological or environmental samples.
Environmental
Food & Beverage
Disease Control
Geology & Mining
Forensics
LabTech Flex-MVP Automatic Parallel Vacuum Concentrator

Related Products

Online Inquiry

Contact Us Linkedin Feedback
TOP

BackTop

What was the purpose of your visit today?
How can we improve your labtechworld.com experience?
Please rate your labtechworld.com experience:
Not Satisfied Extremely Satisfied
1 2 3 4 5 6 7 8 9 10

Your feedback is for internal use only, View the LabTech Privacy Policy.

If your request requires a reply from LabTech, please Contact Us.